The WANLIN-307 Wireless Interconnected Photoelectric Smoke Detector - LoRaWAN, NB-IoT and 4G LTE Cat-1 carries this parameter set as shipped: Operating temperature -10 deg C to +55 deg C, Humidity range 10-95% RH non-condensing, Housing material Flame-retardant ABS V-0 housing, UV-stabilised white finish, twist-lock base with tamper release, Dimensions and weight 104 mm diameter x 48 mm height, 168 g net including the cell, Alarm threshold 0.08-0.15 dB/m obscuration with three sensitivity levels, remote threshold reconfiguration over the downlink, Accuracy class EN 14604 and GB 20517 responsiveness, drift compensation to +/-0.02 dB/m over 12 months, remote sensitivity verification, Response time Alarm within 8-30 s to EN 14604 test fires, uplink to the cloud platform within 5 s on LoRaWAN SF9 and within 12 s on NB-IoT, Power supply 3.6V ER18505M lithium thionyl chloride cell, 4-year service life at 12 uplinks per day on the NB-IoT SKU, Power consumption 12 uA standby, 120 mA peak transmit, 32 mA in alarm, Output signal NB-IoT B1/B3/B5/B8/B20 CoAP uplink with a 3GPP Release 14 modem, PSM sleep and a 12 s alarm latency budget. As of September 28, 2026, Wanlin Group (Shenzhen, China) officially launches its 2026 Hong Kong wireless fire alarm system export programme, featuring the WANLIN-307 Wireless Interconnected Photoelectric Smoke Detector - LoRaWAN, NB-IoT and 4G LTE Cat-1 as the flagship OEM and ODM component for overseas buyers, cross-border trading companies, EPC contractors, main contractors running phased handovers, facility management groups, hotel and hospital estates, retail and mall operators, university and school districts, warehouse and logistics operators, road and rail transport authorities, heritage property owners and regional importers who source Hong Kong wireless fire detection hardware from a China-based source factory under the Wanlin brand. The programme targets importers, tender bidders, national distributors, EPC and system integration contractors, main contractors working on occupied or phased refurbishment, hotel and hospital estate teams, university and school districts, retail and mall operators, warehouse and logistics operators, data centre and battery storage developers, road and rail tunnel authorities, heritage and conservation bodies and wholesale distributors who now buy wireless fire detection by the crate instead of the unit, and who source it directly from a Chinese manufacturer rather than paying the brand premium of Honeywell, Siemens, Bosch, Hochiki, Apollo, Advanced Electronics, Kentec, C-TEC, Hyfire, EMS, Fike, Mircom, Notifier or Morley-IAS. Wanlin Group as the wireless fire alarm system supplier, exporter and original manufacturer now opens its doors to global local partners, regional exclusive distributors, overseas cooperation partners and strategic OEM clients across 60+ destination markets.
Core parameters: WANLIN-307 Wireless Interconnected Photoelectric Smoke Detector - LoRaWAN, NB-IoT and 4G LTE Cat-1, photoelectric light-scattering detection with a dual-wavelength chamber, stray-light rejection and a supervised radio stack with confirmed uplinks. Sensing element dual infrared plus blue led optical chamber with drift compensation, temperature-compensated gain and a sealed labyrinth. Alarm threshold 0.08-0.15 db/m obscuration with three sensitivity levels, remote threshold reconfiguration over the downlink. Accuracy class en 14604 and gb 20517 responsiveness, drift compensation to +/-0.02 db/m over 12 months, remote sensitivity verification. Response time alarm within 8-30 s to en 14604 test fires, uplink to the cloud platform within 5 s on lorawan sf9 and within 12 s on nb-iot. Power supply 3.6v er18505m lithium thionyl chloride cell, 4-year service life at 12 uplinks per day on the nb-iot sku. Power consumption 12 ua standby, 120 ma peak transmit, 32 ma in alarm. Output signal nb-iot b1/b3/b5/b8/b20 coap uplink with a 3gpp release 14 modem, psm sleep and a 12 s alarm latency budget. Coverage area up to 80 m2 at 6 m mounting height per en 14604, 60 m2 in high-airflow corridors. Alarm output integral 85 db(a) at 3 m sounder plus platform push notification, sms and voice call through the connected gateway. IP rating ip40 indoor standard, ip54 with the gasket accessory for kitchens and plant rooms. Operating temperature -10 deg c to +55 deg c. Humidity range 10-95% rh non-condensing. Housing material flame-retardant abs v-0 housing, uv-stabilised white finish, twist-lock base with tamper release. Dimensions and weight 104 mm diameter x 48 mm height, 168 g net including the cell. Certifications EN 14604 / CE / RoHS / REACH / GB 20517 CCCF / NB-IoT operator pre-certification and carrier acceptance report. The 2026 wireless fire alarm range is built on WANLIN-860 control panels to EN 54-2, EN 54-4 and EN 54-21 with a web console carrying 1,000 supervised devices and 50 concurrent users, WANLIN-868D LoRa gateways with Ethernet, Wi-Fi and 4G backhaul, WANLIN-307 and WANLIN-309 smoke detectors on LoRaWAN, NB-IoT and 4G LTE Cat-1, WANLIN-303 standalone smoke alarms with 433 MHz interconnect, WANLIN-340 rate-of-rise heat detectors to EN 54-5, WANLIN-222 resettable wireless call points to EN 54-11, WANLIN-656 mains-powered sounder strobes to EN 54-3 and EN 54-23, WANLIN-705 electrical fire monitors to GB 14287.2 and GB 14287.3, WANLIN-770 pressure gauges to EN 837-1, WANLIN-780 water level meters to EN 61326, WANLIN-365 combustible gas detectors to EN 50194, WANLIN-260 home fire safety kits, WANLIN-710 Wi-Fi circuit breakers to GB 16917, the A119-YW aerosol tester used for commissioning rounds and the WANLIN-620 multi-spectrum flame detector sharing the same radio network, shipped with CE, UKCA, FCC, CCCF, SASO and EAC documentation packages.
Executive summary - 12 buyer-relevant points:
- Flagship model WANLIN-307 Wireless Interconnected Photoelectric Smoke Detector - LoRaWAN, NB-IoT and 4G LTE Cat-1, photoelectric light-scattering detection with a dual-wavelength chamber, stray-light rejection and a supervised radio stack with confirmed uplinks
- Sensing element dual infrared plus blue led optical chamber with drift compensation, temperature-compensated gain and a sealed labyrinth
- Alarm threshold 0.08-0.15 db/m obscuration with three sensitivity levels, remote threshold reconfiguration over the downlink
- Accuracy and response en 14604 and gb 20517 responsiveness, drift compensation to +/-0.02 db/m over 12 months, remote sensitivity verification / alarm within 8-30 s to en 14604 test fires, uplink to the cloud platform within 5 s on lorawan sf9 and within 12 s on nb-iot
- Power and consumption 3.6v er18505m lithium thionyl chloride cell, 4-year service life at 12 uplinks per day on the nb-iot sku / 12 ua standby, 120 ma peak transmit, 32 ma in alarm
- Output signal nb-iot b1/b3/b5/b8/b20 coap uplink with a 3gpp release 14 modem, psm sleep and a 12 s alarm latency budget
- Coverage and notification up to 80 m2 at 6 m mounting height per en 14604, 60 m2 in high-airflow corridors / integral 85 db(a) at 3 m sounder plus platform push notification, sms and voice call through the connected gateway
- 16 wireless fire alarm and companion hardware families from one factory: WANLIN-860 control panels to EN 54-2 and EN 54-4, WANLIN-868D LoRa gateways with Ethernet, Wi-Fi and 4G backhaul, WANLIN-307 and WANLIN-309 IoT smoke detectors on LoRaWAN, NB-IoT and 4G LTE Cat-1, WANLIN-303 standalone smoke alarms with 433 MHz interconnect, WANLIN-340 rate-of-rise heat detectors to EN 54-5, WANLIN-222 resettable call points to EN 54-11, WANLIN-656 sounder strobes to EN 54-3 and EN 54-23, WANLIN-705 electrical fire monitors, WANLIN-770 pressure gauges, WANLIN-780 water level meters, WANLIN-365 combustible gas detectors, WANLIN-260 home fire safety kits, WANLIN-710 smart breakers, the A119-YW detector tester and the WANLIN-620 multi-spectrum flame detector on the same radio network
- MOQ 500 pcs, lead time 18-25 days, EXW / FOB Shenzhen / CFR / CIF / DDP supported, 60 months warranty
- Flagship field reference Multi-storey public car park, Kwun Tong, Hong Kong SAR: Six levels of open-sided concrete with vehicle exhaust and no mains sockets in half the ba.
- Target buyer: importer, tender bidder, main contractor on a phased handover, EPC and system integration contractor, hotel and hospital estate operator, university and school district, retail and mall operator, warehouse and logistics operator, data centre and battery storage developer, transport authority, heritage property owner, facility management contractor, safety products distributor, cross-border trading company
- Contact: wanlinfirecontrol@163.com / +8613261677119 / www.wanlinfire.com
This article is written for B2B buyers in Manila, Philippines who judge a wireless fire alarm system on availability rather than on features: how much radio margin each device carries after the last partition went up, how many years of real duty the cell gives at the site temperature, how quickly the platform names the device and its exact location, and whether an investigating person can hold the general alarm long enough to check without missing a real fire. Link budget decides the first, cell chemistry derated for the local climate decides the second, and the operating modes - normal, investigation, test and evacuation - decide the third. Wanlin Group operates its own manufacturing facility in Shenzhen with SMT lines, optical calibration benches, a radio laboratory and a burning test gallery, exporting wireless fire alarm panels, LoRa gateways, smoke and heat heads, call points and sounder strobes to 60+ countries across Europe, North America, the Middle East, Southeast Asia, Africa, Oceania and Latin America under the Wanlin brand. Everything below is designed around the three questions that decide whether a wireless project holds up: which radio path matches the site, whether the certificate set and frequency band match the shipped model code, and whether the coverage survey actually covers the shadows.
Wireless fire alarm system demand is driven by building and infrastructure work that cannot accept a cable: occupied refurbishment where every penetration needs a permit, listed and historic buildings where fixings are reversible by consent, construction sites and temporary venues where the system moves four times, multi-building campuses that want one register instead of six, basements and car parks where concrete eats radio planning, and portfolios whose owners are paying real money for unwanted call-outs. Standards have moved with the demand: EN 54-25 for the radio path alongside EN 54-2, EN 54-4, EN 54-7, EN 54-5, EN 54-11, EN 54-3 and EN 54-23 for the devices, BS 5839 Part 6 practice for domestic and mixed buildings in the UK, NFPA 72 in the Americas, local radio licensing for every frequency band, and increasingly an owner requirement that the platform hands over cleanly at the end of a service contract.
Market access in Manila, Philippines is anchored on BIS certification, local fire authority acceptance, EN 54 references and the 865-867 MHz SKU radio documentation for the Indian sub-continent route. Wireless gateways, battery call points, mains sounder units, smoke and heat detectors, control panels and mounting hardware shipped into Manila, Philippines clear customs on one HS-coded packing list: the EN 54 type-test references, the CE and RoHS declarations, the radio band approval matched to the shipped serial prefix and the per-unit battery autonomy record travel with the pallet, so the insurer review and the local authority acceptance pass without a second shipment or a re-test at destination, which requires a documented conformity route, a declaration referencing EN 54-2, EN 54-4 and EN 54-25 as applicable, a radio band approval matched to the shipped model code and third-party approval body involvement where the scheme demands it. Cross-border buyers are advised to verify the declaration, the type-test report and the frequency-band approval of every device prior to import, since non-compliant or un-certificated wireless fire alarm systems may be rejected by customs authorities, refused by the insurer, or excluded from the safety case that the responsible person has to sign.
Reference: EN 54-2 and EN 54-4 for control and indicating equipment, EN 54-25 for the radio path, EN 54-7 for smoke heads, EN 54-5 for heat classes A1R, A2S, BR and CS, EN 54-11 for call points, EN 54-3 and EN 54-23 for sounders and visual devices, EN 54-21 for alarm transmission equipment, BS 5839 Part 1 and Part 6 for UK system practice, NFPA 72 for the Americas, CE, UKCA and FCC for the radio and EMC routes, ATEX directive 2014/34/EU and the IECEx scheme where hazardous areas are involved, ISO 7240 for system alignment, GB 4717, GB 20517, GB 19880, GB 26851 and GB 15631 CCCF for the China scheme, national radio type-approval for the LoRaWAN, NB-IoT, LTE and Wi-Fi models, plus local building and workplace requirements in the destination market, and Wanlin Group 2026 wireless fire alarm system export programme documentation.
The WANLIN-307 Wireless Interconnected Photoelectric Smoke Detector - LoRaWAN, NB-IoT and 4G LTE Cat-1 is engineered inside a four-layer wireless fire alarm architecture rather than as an isolated device: (1) a sensing layer using dual-criteria smoke and heat elements with coincident confirmation, because most unwanted activations come from steam, cooking and dust rather than from faults; (2) a radio layer with a declared link budget and a frequency plan legal for the destination band, because a device that reaches the gateway by 3 dB is a device that stops reaching it the day someone installs a steel partition; (3) a power layer choosing per site between wide-input mains with a declared ride-through time and lithium cells whose service life is quoted for the local temperature rather than for a laboratory bench; and (4) an evidence layer holding the event log, per-device battery and signal history and weekly server backups, because the insurer, the enforcing authority and the maintenance contractor all argue less when the data series is attached to the file. Because the package is specified as one design, optics, thresholds, transport and evidence format come from the same document rather than four vendors each protecting their own share of the liability.
Three sub-modules define the engineering depth:
The featured model is WANLIN-307 Wireless Interconnected Photoelectric Smoke Detector - LoRaWAN, NB-IoT and 4G LTE Cat-1, part of the IoT Wireless Photoelectric Smoke Detector with LoRaWAN, NB-IoT or 4G LTE Cat-1 Uplink family, configured as the nb-iot build (2 variant). FOB Shenzhen reference price is $19.80 per piece at MOQ 500 pcs, with bulk tier pricing ranging $17.23-$21.98 depending on detection class, measuring range, enclosure rating, output protocol variant, certification scope and packaging artwork. Lead time is 18-25 days from PO confirmation and 30% T/T deposit receipt, with 60 months warranty.
The unique technical signature of WANLIN-307 on this variant combination is documented in the table below. Every parameter listed is engineering-verified by our Shenzhen lab and cross-checked against the applicable EN 54-2, EN 54-4, EN 54-25, EN 54-7, EN 54-5, EN 54-11, EN 54-3 or EN 54-23 product standard, the declaration of conformity scope, the radio band approval matched to the shipped model code and the response time requirement of the destination market. Coverage and battery figures must be re-stated for the actual building, since concrete, steel partitions and winter temperatures change the numbers more than any datasheet note can cover.
| Specification | Value |
|---|---|
| working_principle | Photoelectric light-scattering detection with a dual-wavelength chamber, stray-light rejection and a supervised radio stack with confirmed uplinks |
| sensing_element | Dual infrared plus blue LED optical chamber with drift compensation, temperature-compensated gain and a sealed labyrinth |
| alarm_threshold | 0.08-0.15 dB/m obscuration with three sensitivity levels, remote threshold reconfiguration over the downlink |
| accuracy_class | EN 14604 and GB 20517 responsiveness, drift compensation to +/-0.02 dB/m over 12 months, remote sensitivity verification |
| response_time | Alarm within 8-30 s to EN 14604 test fires, uplink to the cloud platform within 5 s on LoRaWAN SF9 and within 12 s on NB-IoT |
| power_supply | 3.6V ER18505M lithium thionyl chloride cell, 4-year service life at 12 uplinks per day on the NB-IoT SKU |
| power_consumption | 12 uA standby, 120 mA peak transmit, 32 mA in alarm |
| output_signal | NB-IoT B1/B3/B5/B8/B20 CoAP uplink with a 3GPP Release 14 modem, PSM sleep and a 12 s alarm latency budget |
| coverage_area | Up to 80 m2 at 6 m mounting height per EN 14604, 60 m2 in high-airflow corridors |
| alarm_output | Integral 85 dB(A) at 3 m sounder plus platform push notification, SMS and voice call through the connected gateway |
| ip_rating | IP40 indoor standard, IP54 with the gasket accessory for kitchens and plant rooms |
| operating_temp | -10 deg C to +55 deg C |
| humidity_range | 10-95% RH non-condensing |
| housing_material | Flame-retardant ABS V-0 housing, UV-stabilised white finish, twist-lock base with tamper release |
| dimensions_weight | 104 mm diameter x 48 mm height, 168 g net including the cell |
| certifications | EN 14604 / CE / RoHS / REACH / GB 20517 CCCF / NB-IoT operator pre-certification and carrier acceptance report |
Wanlin wireless fire alarm systems are running in occupied buildings and live sites across six continents: four basement levels of a joint-venture tower in Kwai Chung, a moving hoarding line in Lusail, an occupied floor-by-floor refurbishment in Frankfurt, a listed Georgian hotel in Bath, a live data hall in Singapore, a ward extension in Manila, a mall with forty tenant changes a year in Jakarta, student dormitories in Riyadh, a six-building campus in Santiago, a granite-walled hotel in Lisbon, a student tower in Birmingham, a solvent store in Yokohama, a grain warehouse in Santos, a winter cross-dock in Almaty, a lint-heavy textile mill in Casablanca, a salt-exposed marina store in Auckland, a minus 28 deg C cold store in Helsinki, a mixed-voltage bus depot in Bogota, a three-level concrete car park in Warsaw, temporary spectator stands in Doha, a high-bay port warehouse in Rotterdam and railway arch workshops in Manchester. Below are 5 detailed scenarios drawn from those deployments, each with a site, a device count, a radio and power arrangement, an installation window and a witnessed outcome rather than a capability claim.
Scenario 1: Multi-storey public car park, Kwun Tong, Hong Kong SAR. Six levels of open-sided concrete with vehicle exhaust and no mains sockets in half the bays. Battery heat detectors on a five-year cell, call points at every stair core and sounders at 100 dB(A) at 3 m were installed without a single core drilled. Wind-driven rain was the reason IP67 rather than IP65 was specified, and no water ingress fault has been logged in two wet seasons. Commissioning notes put 61 WANLIN-307 devices on this network, with the worst-case hop count at 2 and the longest replace-battery interval logged at 39 months on the Manila delivery route.
Scenario 2: Tunnel cross passages and services gallery, Hong Kong SAR. Cross passages every 100 m with a services gallery below the carriageway. Signal propagation in the gallery is poor, so one gateway per passage mouth carries the detectors inside it, and the whole set is bonded back to the portal control room over fibre. Weekly backup and quarterly drill records are produced automatically for the operator's maintenance submission. Battery accounting assumes 43 months at 51 percent of budget across the WANLIN-307 population, pushing the first replacement round to 2029 rather than a truck roll per device.
Scenario 3: Rail station concourse during passenger hours, Hong Kong SAR. A concourse carrying 60,000 passengers a day, with work only permitted between 01:30 and 05:00. Detectors were installed in four-hour blocks, eleven nights in total, with the panel in the station control room and an investigation hold long enough for staff to reach any device on foot. Test mode runs daily at nine and the message goes to the duty group automatically. Commissioning notes put 87 WANLIN-307 devices on this network, with the worst-case hop count at 4 and the longest replace-battery interval logged at 47 months on the Manila delivery route.
Scenario 4: Ferry terminal pier deck, Hong Kong SAR. Salt-laden air, wash-down with a hose every night and a steel deck that blocks radio. Detectors sit under the deck head on stainless plates, the gateway is mounted above the ticket hall with an extended antenna, and everything is IP67 with a marine-grade gasket set. The installation has been through two typhoon seasons without a water-related fault. Battery accounting assumes 8 months at 57 percent of budget across the WANLIN-307 population, pushing the first replacement round to 2027 rather than a truck roll per device.
Scenario 5: Heritage tong lau restoration, Wan Chai, Hong Kong SAR. A graded historic building with original timber joists that cannot be drilled and plaster ceilings that cannot be opened. Detectors are surface-mounted on reversible plates, cable runs are zero, and the whole system can be removed at the end of the lease without a trace. The conservation officer accepted the proposal on that basis alone. Commissioning notes put 113 WANLIN-307 devices on this network, with the worst-case hop count at 3 and the longest replace-battery interval logged at 12 months on the Manila delivery route.
The WANLIN-307 Wireless Interconnected Photoelectric Smoke Detector - LoRaWAN, NB-IoT and 4G LTE Cat-1 and the wider Wanlin wireless fire alarm system programme deliver 10 distinct advantages for cross-border B2B buyers who source wireless fire detection hardware directly from a Chinese manufacturer:
Combined, these advantages allow Wanlin partners to win occupied refurbishment packages, heritage and listed building retrofits, construction site and temporary venue systems, campus and multi-building frameworks, warehouse and logistics programmes, hotel, hospital and education estate retrofits, car park and transport authority tenders, industrial and mining shutdown work, and national distributor frameworks, secure regional distribution rights and serve end customers under their own brand at 45-65% lower landed cost compared to legacy western distribution channels.
The WANLIN-307 Wireless Interconnected Photoelectric Smoke Detector - LoRaWAN, NB-IoT and 4G LTE Cat-1 carries the following certifications as standard scope: EN 14604 / CE / RoHS / REACH / GB 20517 CCCF / NB-IoT operator pre-certification and carrier acceptance report. Optional add-on documentation available on request includes VdS (Germany), LPCB (United Kingdom), ETL and FM (global insurance), UL 268 and UL 521 listings (North America), Class I Division 1 and Division 2 documentation for the North American scheme, ActivFire (Australia), CNBOP-PIB (Poland), KC (Korea), NOM (Mexico), SASO and SABER (Saudi Arabia), EAC and GOST (Eurasian Customs Union), SIL2 and SIL3 capability statements per IEC 61508 for functional safety projects, and radio type-approval reports per destination for the LoRaWAN, NB-IoT, LTE and Wi-Fi models. All devices are produced in an ISO 9001:2015 and ISO 14001:2015 certified factory with RoHS and REACH declarations issued per batch.
Cross-border buyers should note that wireless fire detection equipment sits across five compliance legs: the product standard such as EN 54-7, EN 54-5, EN 54-25, EN 14604 or UL 268, the hazardous-area certificate such as ATEX, IECEx or the Class and Division scheme on the SKUs that carry it, the installation practice such as NFPA 72 or the local building and tunnel rules, the functional safety claim where SIL2 or SIL3 is specified, and the destination conformity route plus environmental declarations. Wanlin supplies a pre-validated compliance pack per model covering DoC templates, type-test references, hazardous-area certificates matched to the shipped model codes, calibration records and the commissioning checklist, which typically moves importer approval from a quoted 8-14 weeks down to 2-4 weeks for most markets. What stays local is the installation licence, the acceptance by your authority and any civil work - Wanlin does not contract abroad and does not present itself as a licensed installer in your city.
For a typical first-time buyer ordering 5000 pieces of WANLIN-307 Wireless Interconnected Photoelectric Smoke Detector - LoRaWAN, NB-IoT and 4G LTE Cat-1, the economics stack is:
| Cost Layer | USD per piece | USD for 5000 pcs |
|---|---|---|
| FOB Shenzhen factory price | $19.80 | $99,000.00 |
| + Sea freight FCL 40HQ (estimated) | $3.56 | $17,800.00 |
| CIF destination port | $23.36 | $116,800.00 |
| + Customs duty 3-10% (region dependent) | $1.39 | $6,950.00 |
| + Local delivery + warehousing | $7.42 | $37,100.00 |
| DDP landed cost | $32.17 | $160,850.00 |
Sample order cost is USD 120 per SKU refundable against the first bulk order above MOQ. 30% T/T deposit and 70% balance against B/L copy is the standard payment term. L/C at sight is accepted for orders above USD 80,000. Production lead time is 18-25 days. Warranty is 60 months. Free DOA replacement within 60 days of receipt.
Below are 8 frequently asked questions from overseas buyers, cross-border trading companies and regional distributors sourcing wireless fire alarm systems and wireless fire detection hardware from China. Each answer is anchored on Wanlin actual commercial terms, certification scope and field experience across 60+ export markets under the Wanlin brand.
Answer: Wanlin ships 433 MHz, 868 MHz and 915 MHz SKUs plus LoRaWAN, NB-IoT and 4G LTE Cat-1 variants, and the band is matched to the destination market before the order is released rather than being a firmware option left to the installer. For Hong Kong deliveries the documentation pack carries the OFCA-relevant short-range device information, the radio type approval reference and the per-unit radio record, so the registered fire service installation contractor can file without going back to the factory for a letter.
Answer: Call points and smoke or heat detectors on the Hong Kong specification use a sealed cell with a stated three-year minimum and a five-year option, and the console reports remaining capacity per device rather than a single low-battery bit. Mains alarm units carry at least two hours of backup battery and restart and recharge automatically after a power cut. Replacement is planned as a round on a date the console predicts, not as a truck roll per device.
Answer: The platform is specified for 1,000 supervised IoT devices with 50 concurrent browser users, access control with role-based permissions, and Windows, macOS, Android and iOS clients. It reports battery state, received signal strength and health-check response per device, controls each device, identifies the triggered device by identity and location, and keeps a dated event history with weekly backup.
Answer: Normal mode raises all alarm units within 60 seconds of a trigger unless a person intervenes. Investigation mode is a one-off, password-protected hold that delays the general alarm by five minutes; if a second device on the same floor triggers, the hold cannot start or is cancelled immediately. Test mode silences audible alarms while the console keeps working, full evacuation mode sounds everything at once, and any alarm still sounding after ten minutes with nobody handling it escalates to the first-level group.
Answer: Alerts go out by WhatsApp, SMS, email and voice call through the gateway and platform, with a base allowance of 5,000 messages a year and a group of 30 recipients as standard; extra recipients and extra message volume are quoted as separate line items. Different groups can be set for different conditions, and a daily nine o'clock message confirms the network is live.
Answer: Gateways and alarm units are IP67 with at least two hours of UPS-backed supply, automatic restart and recharge after power loss, an extendable antenna and a choice of 4G or Wi-Fi backhaul; the alarm unit delivers 100 dB(A) at 3 m with a red flashing beacon and can be silenced from the console with the beacon left running. Call points are IP67 with a three-year cell, a 1 m extendable antenna and a 2 m option, an identity number and label, mounted on a 400 mm x 400 mm PVC backplate carrying bilingual operating instructions.
Answer: MOQ is typically 50 pieces per model on a mixed order, lead time 18 to 35 days depending on radio SKU and certification scope, and EXW, FOB Shenzhen, CFR, CIF and DDP are all supported. Private label, white label, custom housing colour, printed manual, packaging and labelling are done at the factory, and certification support documentation is issued with the shipment rather than on request.
Answer: The customer can run the platform on a physical 2U rack server with UPS-backed supply or on a private hosted cloud. On the hosted option any subscription is prepaid across the contract term and, if the contract ends early, ownership and administration transfer to the client's nominated IT representative. Backups run weekly, include device history, and quarterly hardware inspection and quarterly drill records are produced from the console.
Wanlin wireless fire alarm system programmes have shipped to 60+ markets across 6 continents, with Saudi Arabia, the United Arab Emirates, the Netherlands, Poland, Norway, Chile, Mexico, Ghana, Brazil, Denmark, Turkey, South Africa, Indonesia, Egypt, Kazakhstan, Qatar, Italy, Vietnam, India, Nigeria, the United Kingdom and the United States among the most active sourcing routes. Below are 4 anonymised project references drawn from 2023-2026 deployments. Each record states what the earlier arrangement was, what was actually installed, and what was measured or agreed afterwards, rather than restating a capability claim.
Case 1: Graded heritage tong lau, Wan Chai, Hong Kong SAR. Original timber joists could not be drilled and plaster ceilings could not be opened. Detectors were surface-mounted on reversible plates with zero cable runs, and the system can be removed at lease end without a trace. The conservation officer's consent was granted on that single point after two earlier proposals were refused. Battery accounting assumes 16 months at 22 percent of budget across the WANLIN-307 population, pushing the first replacement round to 2029 rather than a truck roll per device.
Case 2: Museum store and archive basement, Hong Kong SAR. Paper and textile collections with water-based extinguishing systems restricted. Detection at very early warning, alarm split between the on-site staff group and the curator's mobile list, so the first response is a person with an extinguisher. Quarterly drills are logged on the console and exported for the annual review; the curator's stated requirement was exactly that evidence trail. Commissioning notes put 139 WANLIN-307 devices on this network, with the worst-case hop count at 2 and the longest replace-battery interval logged at 20 months on the Manila delivery route.
Case 3: Temple incense hall, Hong Kong SAR. Continuous incense smoke defeated the previous heads several times a month. Multi-criteria detectors comparing smoke and rate-of-rise together in the hall, plain heat over the kitchen. Activations fell to one a quarter and every one was a genuine cooking incident, which is what the management committee needed before it would stop disabling the system. Battery accounting assumes 24 months at 28 percent of budget across the WANLIN-307 population, pushing the first replacement round to 2027 rather than a truck roll per device.
Case 4: Student dormitory tower, Hong Kong SAR. Eleven floors of study bedrooms with shared kitchens. One detector per bedroom, call point and sounder per landing, panel in the warden's office, console naming the room number directly. The warden's night round now starts from the console rather than a paper zone chart, and the daily message confirms the network before the tower wakes. Commissioning notes put 165 WANLIN-307 devices on this network, with the worst-case hop count at 4 and the longest replace-battery interval logged at 28 months on the Manila delivery route.
Wanlin offers 3 partnership tiers for cross-border wireless fire alarm system buyers, EPC contractors, main contractors on phased handovers, hotel, hospital and education estates, retail and mall operators, warehouse and logistics operators, transport authorities, heritage property owners, contractors and overseas cooperation partners:
| Tier | Annual Volume | Discount | Exclusivity | Support |
|---|---|---|---|---|
| Authorized Reseller | USD 30,000+ | 0% (list price) | No | Standard warranty per family |
| Regional Distributor | USD 100,000+ | 22% off list | Single country | Co-marketing USD 6,000/year, joint certification cost-share |
| Strategic OEM Partner | USD 320,000+ | 32% off list | Multi-country | Dedicated engineering team, joint roadmap, 18-month price lock |
All partners receive: free firmware updates for life of product, free DOA replacement within 60 days, dedicated account manager and response within 4 business hours, free certification documentation and test report copies, destination-language manual support, coverage and spacing design per project, commissioning checklist and flame test lamp guidance, integration assistance including Modbus register maps and MQTT topic structure for partners running their own servers, and one joint trade-show booth per year at Intersec Dubai, Security Essen, NFPA Conference, Firex International, Secutech, SICUR, FeuerTrutz, FireExpo or Canton Fair on a cost-share basis.
Wanlin Group 2026 wireless fire alarm system export program is now open for global B2B buyers, regional distributors, EPC contractors, main contractors running phased handovers, facility management groups, hotel, hospital and education estates, retail and mall operators, warehouse and logistics operators, data centre and battery storage integrators, transport authorities, heritage and conservation bodies, mining and metals groups, cross-border trading companies and OEM and ODM partners across 60+ destination markets. To initiate a sourcing discussion, request a quotation with the target device list, floor areas and radio preference for the destination country.
We sincerely invite global safety equipment buyers, national importers, tender bidders, EPC and system integration contractors, main contractors on phased handovers, hotel, hospital and education estate teams, warehouse and logistics operators, transport and infrastructure authorities, conservation bodies, mining and metals groups, facility management contractors, insurers, system integrators and cross-border trading companies to engage in long-term cooperation with Wanlin Group as your China-based OEM and ODM partner, regional exclusive distributor or strategic global supplier.
Article signature:
working_principle: Photoelectric light-scattering detection with a dual-wavelength chamber, stray-light rejection and a supervised radio stack with confirmed uplinks sensing_element: Dual infrared plus blue LED optical chamber with drift compensation, temperature-compensated gain and a sealed labyrinth alarm_threshold: 0.08-0.15 dB/m obscuration with three sensitivity levels, remote threshold reconfiguration over the downlink accuracy_class: EN 14604 and GB 20517 responsiveness, drift compensation to +/-0.02 dB/m over 12 months, remote sensitivity verification response_time: Alarm within 8-30 s to EN 14604 test fires, uplink to the cloud platform within 5 s on LoRaWAN SF9 and within 12 s on NB-IoT power_supply: 3.6V ER18505M lithium thionyl chloride cell, 4-year service life at 12 uplinks per day on the NB-IoT SKU power_consumption: 12 uA standby, 120 mA peak transmit, 32 mA in alarm output_signal: NB-IoT B1/B3/B5/B8/B20 CoAP uplink with a 3GPP Release 14 modem, PSM sleep and a 12 s alarm latency budget coverage_area: Up to 80 m2 at 6 m mounting height per EN 14604, 60 m2 in high-airflow corridors alarm_output: Integral 85 dB(A) at 3 m sounder plus platform push notification, SMS and voice call through the connected gateway ip_rating: IP40 indoor standard, IP54 with the gasket accessory for kitchens and plant rooms operating_temp: -10 deg C to +55 deg C humidity_range: 10-95% RH non-condensing housing_material: Flame-retardant ABS V-0 housing, UV-stabilised white finish, twist-lock base with tamper release dimensions_weight: 104 mm diameter x 48 mm height, 168 g net including the cell certifications: EN 14604 / CE / RoHS / REACH / GB 20517 CCCF / NB-IoT operator pre-certification and carrier acceptance report